EPC-3D-Diff: Equivariant Physics Consistent Conditional 3D Latent Diffusion for CBCT to CT Synthesis
The article presents EPC-3D-Diff, a new framework for synthesizing CT images from CBCT data. This method addresses issues related to scatter, noise, and artifacts in CBCT imaging, improving the accuracy of Hounsfield Units. The framework demonstrates significant performance enhancements over existing methods in both phantom and clinical datasets.
- ▪EPC-3D-Diff introduces a projection domain equivariance loss based on acquisition physics.
- ▪The framework utilizes a lightweight 3D autoencoder for efficient conditional diffusion in a compact latent space.
- ▪It achieved improvements of +7.4 dB in PSNR for phantom data and +1.8 dB for clinical data compared to state-of-the-art methods.
arXiv cs.AI files mainly under ai research. We currently carry 1,128 of its stories.
Story provenance
Source · retrieval · rights · ranking — open for full record
inspect →
Story provenance
Attribution is not the same as permission. This drawer separates discovery metadata, excerpts, WeSearch-generated summaries, reuse status, and whether the publisher receives the visit. Nothing here claims a legal grant the publisher has not made.
Record
| Original publisher | arXiv cs.AI |
| Canonical URL | https://arxiv.org/abs/2605.20470 |
| Publication time | Fri, 22 May 2026 00:00:00 -0400 |
| Retrieval time | 2026-05-22T04:02:00.009Z |
| Last seen | 2026-05-22T04:02:00.009Z |
| Headline source | Publisher (no WeSearch rewrite) |
| Excerpt source | publisher body |
| Excerpt method | First ~120 words (~800 chars) of extracted publisher body, fair-use limited. |
| Summary | WeSearch · cerebras-chat (WeSearch summarizer) |
| Summary source text | contentText |
| Citation coverage | Summary is a WeSearch-generated derivative; primary citation is the original publisher URL. |
| Cluster | Vxd068sL5kPY |
| Cluster logic | Grouped by semantic title/content similarity across sources within a rolling window. Same-publisher template collisions are excluded from coverage comparison. |
| Ranking reason | Story pages are not engagement-ranked. Hub feeds use recency, with optional source-diversified chronological ordering (cap consecutive stories per source). No personalized ranking. |
| Publisher visit | Yes — open original |
| Substitutes article? | No — link-out required for full text |
Rights status (four layers)
WeSearch handling by dimension
| Indexing | May the item be indexed (stored, ranked, made findable)? | Allowed |
| Snippet | May a short excerpt of the publisher's text be shown? | Allowed |
| AI summary | May WeSearch generate its own short summary of the article? | Limited |
| Retrieval / RAG | May the content be exposed for third-party retrieval-augmented generation? | Not asserted |
| Model training | May the content be used to train AI models? | Not asserted |
| Commercial reuse | May the content be reused commercially? | Not permitted |
Basis: Derived from the published RSS/Atom feed. Contact: [email protected]. Reviewed: 2026-07-24.
Opening excerpt (first ~120 words) tap to expand
Computer Science > Computer Vision and Pattern Recognition arXiv:2605.20470 (cs) [Submitted on 19 May 2026] Title:EPC-3D-Diff: Equivariant Physics Consistent Conditional 3D Latent Diffusion for CBCT to CT Synthesis Authors:Alzahra Altalib, Chunhui Li, Haytham Al Ewaidat, Khaled Alawneh, Ahmad Qendel, Alessandro Perelli View a PDF of the paper titled EPC-3D-Diff: Equivariant Physics Consistent Conditional 3D Latent Diffusion for CBCT to CT Synthesis, by Alzahra Altalib and 5 other authors View PDF HTML (experimental) Abstract:Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noise, and reconstruction artifacts, limiting Hounsfield Unit (HU) accuracy.
…
Excerpt limited to ~120 words for fair-use compliance. The full article is at arXiv cs.AI.